Aurora Versa Adaptors

Contents

Roche-Cobas Ring Adaptor

Holder for plastic 1.5mL vials and integratable
with VERSA Mini systems. Connects Cobas ring to
Roche LightCycler Carousel. Shown here beside
Roche-Cobas ring (not included). Requires
LightCycler Adaptor (see above).
Rotor-GeneDisc 72 & 100 Adaptor
Holds GeneDisc PCR reaction wells and can be
integrated with VERSA Mini PCR / NAP
workstations. Shown here with GeneDisc ring (not
included).


If you use RG-6000 If you use LightCycler If you use RocheCobas
Carousel Adaptors – For all carousel capable decks, 2 adaptors are required.
LightCycler, GeneDisc or Plate Adapter. Carousel decks have 2 round openings.


Holder for Roche’s LightCycler carousel on VERSA
100 systems with carousel deck. Used for real time
PCR to enhance throughput. The LightCycler
Adaptor is required for users desiring adaptors for
each of the following PCR setup options:
VERSA™ Modules, Decks & Accessories
Mini PCR / NAP Modules:


Universal Shaker Adaptors:

  • VER-ADAP-Carousel
  • VER-ADAP-GeneDisc
  • VER-ADAPRotorGene/RocheCobas


Roche MagNA Pure LC Sample Cartridge Adaptor


For extraction of DNA from patient samples.

Holds
VER-ADAP- 32-well MagNA PureLC Cartridge.
MagNA Pure-32
Shaker-NAP


Controls 96-well plate agitation in the range of
100-2000 rpm in both clockwise and counterclockwise directions for specified periods of time.

It can be integrated with all VERSA liquid handling
systems.


Heater-Shaker-MiniPCR


Controls 96-well plate agitation in the range of 100-
2000 rpm in both clockwise and counter-clockwise
directions for specified periods of time. Compatible
with all VERSA Liquid Handling Workstations. Range


Heater-Shaker-LLE


Controls 96-well plate agitation in the range of
100-2000 rpm in both clockwise and counterclockwise directions for specified periods of
time. Compatible with VERSA LLE. Range from
room temperature-95°C.


Shaker-LLE


Controls standard plate agitation in the range
of 100-2000 rpm in both clockwise and
counter-clockwise directions for user specified
periods of time. Clamps hold plates in place. It
can be integrated with VERSA LLE.

  • VER-SH
  • VER-SH-H
  • VER-SH-CVER-SH-HC


Plate Transport System


Used to transport plates from one position to
another. Integrated with VERSA Mini NAP.
Gripper
The Gripper controls plate movement from one
deck position to any other deck position on the
platform.

Compatible with VERSA 1100, 2000
and 3000 systems.

  • VER-PTS
  • VER-PTS-GRP


Magnet for PCR Plates(96-well)
The Magnetic Bead Separator is a 96-well
format adapter that is used to separate beads
used during nucleic acid isolation protocols on
VERSA NAP.

Adaptor has small holes and
supports 96-well PCR plates.
VER-MBS-PCR
Magnet for Round-well Plates (96-well)
The Magnetic Bead Separator is a 96-well
format adapter that is used to separate beads
used during nucleic acid isolation protocols on
VERSA NAP. Adaptor has larger holes and
supports 96-well round-bottom plates.


VER-MBS-RBP
Nitrogen Manifold for 48-well Plates
Alphanume ri c a l l y ma r k ed for e a s y
identification. Ideal for drying samples in
liquid-liquid extraction. Compatible with
VERSA Mini LLE workstations.


VER-NM-48


RG-6000 Ring Adaptor
Holder for plastic 0.1mL vials and integratable
with VERSA Mini systems. Connects RG-6000 ring
to Roche LightCycler Carousel. Shown here beside
RG-6000 ring (not included). Requires LightCycler
Adaptor (see above).


VER-ADAPRotorGene/RocheCobas


Nitrogen Manifold for 96-well Plates
Alphanumeri c a l l y ma r ked for ea s y
identification. Ideal for drying samples in
liquid-liquid extraction. Can be integrated
with VERSA Mini LLE Systems.
VER-NM-96


VERSA™ Modules, Decks & Accessories


Taper Tube Adaptor (6×8, 1.5 mL tubes)
48 x 10.5mm Eppendorf, 1.5 mL tube adaptor
compatible with VERSA Mini PCR and VERSA
NAP. Tubes are used without lids.
Conical (Eppendorf) Microfuge Tube Holder
Adaptor Set (4×8, 1.5mL tubes)
Adaptor for 32 microfuge tubes with hinged
caps. It can be integrated with all VERSA liquid
handling workstations. 2-piece set contains
tube with hinged lid holder and tube lifter.


Vial Adaptor (6×8, 2.0 mL tubes)
Alphanumerically marked for easy
identification.

Commonly used as a storage
system for 40 x 9 mm vials for liquid-liquid
extraction.

Plate compatible with VERSA Mini
PCR and VERSA NAP.


Vial Adaptor(6×8, 2.0 mL tubes)


Commonly used for extraction protocols
requiring placement of vials on shaker. May be
used as a storage system for32 x 11 mm vials for
liquid-liquid extraction. Plate compatible with
VERSA Mini PCR and VERSA NAP.
Tube Adaptor(4×6, 15 mm tubes)
100 x 15 mm test tube adaptor used as a
storage system. Compatible with VERSA Cap
Piercing.


Tube Adaptor (6×8, 11 & 12 mm tubes)


75 x 11 mm test-tube adaptor. Can be used as a
storage system. Compatible with VERSA
workstation for liquid-liquid extraction.
Universal Temperature Modulation Modules:
Plate Heater-Cooler
Heater-cooler compatible with plate, vial and
tube adaptors. Compatible with VERSA
systems. Range from 4-95°C.
VER-PCH-Flat

  • Reagent Block Type A
    The reagent block keeps the reagents at a
    controlled temperature ranging from 1˚C up
    to 80˚C. It contains 16 places for 0.2mL, 12 for
    0.5mL, 5 for 1.5mL and 6 for 5-7mL. It can be
    integrated with all VERSA liquid handling
    workstations.
  • Reagent Block Type B
    The reagent block keeps the reagents at a
    controlled temperature ranging from 1˚C up
    to 80˚C. It contains 16 places for 0.2mL, 8 for
    0.5mL, 8 for 1.5mL and 3 for 5-7mL. It can be
    integrated with all VERSA liquid handling
    workstations.
  • Reagent Block Type C
    The reagent block keeps the reagents at a
    controlled temperature ranging from 1˚C up
    to 80˚C. It can hold 30mL to 50mL volume. It
    can be integrated with all VERSA liquid
    handling workstations.

References

  • VER-RBC-A
  • VER-RBC-B
  • VER-RBC-C


Universal Platform Adaptors:


Plate Cooler: Portable Hybrid Plate / Cooler


Adaptor Top (96-well)
strip tubes
To used as a cooler plate p
prior to use
Fits 96-well round plates or 0.2 mL
Can be used as PCR plate or as cooler top.
Used in PCR prep and culture plate
applications. ut in
refrigerator .

  • VER-ADAP-PCHYBRID TOP
  • VER-ADAP-CTH
  • VER-ADAP-TUBE-48-10.5mm
  • VER-ADAP-VIAL-48-9mm
  • VER-ADAP-VIAL-48-11mm
  • VER-ADAP-TUBE-48-11mm
  • VER-ADAP-TUBE24-15x100mm-V-Cap
  • Vial Adaptor (5×7, 2.0 mL vials)


Commonly used for extraction protocols
requiring placement of vials on shaker. May be
used as a storage system for 32 x 12 mm vials for
liquid-liquid extraction. Plate compatible with
VERSA Mini PCR and VERSA NAP.

  • VER-ADAP-VIAL-35-12mm
    Tube Adaptor(5×7, 13 mm tubes)
    75 x 13 mm test tube adaptor. May be used as a
    storage system. Compatible with VERSA LLE
    and SPE.
  • VER-ADAP-TUBE-35-13mm
    Tube Adaptor(4×6, 15 mm tubes)
    130 x 15 mm test tube adaptor used as a
    storage system. Compatible with VERSA Cap
    Piercing.
  • VER-ADAP-TUBE24-15x130mm-V-Cap
    Plate Heater-Cooler with fixed Hybrid
    Adaptor (96 well format)
    Heater-cooler compatible with plate, vial and
    tube adaptors. Compatible with VERSA
    systems. Range from 4-95°C.


bio-strip tubes

Fits 96-well round
plates or 0.2 mL Can be used as PCR
plate or as cooler top. Used in PCR prep and
VER-PCH-HYBRID TOP culture plate applications.


VER-PCH-384 TOP
Plate Heater-Cooler with fixed Top Adaptor
(384 well format)
Heater-cooler top compatible with 384 well
PCR plates. Temperature range from 4-95C.
Used in PCR plate preparation applications in
384 well format.


VERSA™ Modules, Decks & Accessories
Strip Tube Adaptor(192-well, 0.1 mL)
Metal adapter to hold 0.1 mL PCR tubes & strip
tubes. It is compatible with all VERSA liquid
handling systems. RotorGene tubes (set of 4)
can be used on this adaptor.


Metal PCR non-skirted Plate / Strip-tube


Adaptor (96-well, 0.2 mL tubes)


It holds 0.2 mL PCR strip tubes and non-skirted
PCR plates. It is compatible with all VERSA
liquid handling systems.
Amplislide Adaptor


Holder for AmpliSpeed slide that performs
thermal cycling reactions on glass slides.

Compatible with all VERSA workstations.
Shown here with single amplislide (not
included).


Universal Tip Box Adaptors:


VER-ADAP-TIP200-METAL


Test Tube Holder – Custom
Test-tube holder for use with the VERSA
Sample Processing Workstation. Please
enquire regarding custom integration of this
item onto a VERSA deck to solve your liquid handling requirements.

  • VER-ADAP-TUBE100-ESP
  • VER-ADAPKONELAB

Plate Adaptor for Konelab Cuvettes


Holder for Konelab Cuvettes. Compatible with
VERSA Environmental Sample Processing
system only. Konelab
Cuvette (not included).
Shown here with

  • VER-ADAP192WELL
  • VER-ADAPPCRPLATE
  • VER-ADAPAMPLISLIDE


Tip-Box Adaptor – Single Channel
Single channel metal tip box for VERSA Gene.
Reinforced metal top supports pressure
produced by single channel head attaching to
tip. Used for 20µL, 50µL and 200µL. Tip box
available for 1000 µL tips also. Compatible with
VERSA 1100.


Tip-Box Adaptor


Metal box to hold tips (20µL, 50µL and 200 µL).
Reinforced to support eight-channel head. Tip
box available for 1000 µL tips also. Compatible
with all VERSA liquid handling systems.
VER-ADAP-TIP200-DIV
Waste Tip Collector Box
Waste tip collector box for collecting
disposable tips. Included in VERSA Mini starter
kit.


5-Channel Pressure Box


ReagentDrop pressure box. Holds 5 x 50mL
tubes. Compatible with VERSA automated
liquid handling systems. Provides an effective
and precise way of dispensing bulk reagent. It
can be integrated with VERSA Mini NAP and
VERSA 1100 NAP systems.


Small & Big Syringe Pump Assembly
25µL(left) and 1000µL(right) syringes capable
of dispensing 1µL-1000µL volumes.
Biosafety-Hood With HEPA + UV
It is also available only as dust cover only,
without HEPA & UV. It can be integrated to
VERSA Mini systems.


Miscellaneous:


VER-WASTETIPBOX
100-HOOD-HEPAUV
Barcode Reader
Fixed position design, plug & play
installation.Scans most common barcode
types e.g. Code 39, code 93,code 128,
interleaved 2 of 5, codabar.NW-7, Korean post
ISBN-ISMN-ISSN, Matrix 2 of 5 etc. Compatible
with VERSA Mini & VERSA1100 series.
Vacuum Manifold
Vacuum manifold assembly for washing the
sample binding plate & also the holder for
sample elution / collection plate. It can be
integrated with VERSA Mini NAP & VERSA 1100
NAP.


VER-VM-WSH + VER-VM-COL
Tube Adaptor (4×6, 15 mm tubes)
100 x 15 mm test tube adaptor used as a
storage system. Compatible with VERSA 1100.
VER-ADAP-TUBE24-15mm-V-Gene
BioSafety-Hood with HEPA+UV
It is also available only as a plain dust cover
without HEPA & UV. It can be integrated to
VERSA 1100.


1100-HOOD-HEPAUV
VERSA™ Modules, Decks & Accessories
Nano Syringe Pipettor


Spotter needle dispenses for as low as 40 nL volumes.
It is used for array printing of DNA / RNA / Protein or
other chemicals. It is compatible with all VERSA liquid
handling workstations. This a fixed needle attached to
a single channel SyringePipettor head. Please enquire
regarding this custom feature.


SyringePipettor (2.5mL barrel with 4”Probe)
Reduces tip consumable costs. Aspirates sample and
dispenses with high precision so that there is no
carryover or contamination. Transfers reagents /
chemicals from reagent racks to tubes or plates. This
custom module consists of a fixed needle attached to
a single channel Syringe-Pipettor head.


Single Channel SyringePipettor (with tip changer) &
Dual Channel ReagentDrop Head & Plate Transporter

Metal tip barrel for disposable tips combined with a
plate transporter. Compatible with VERSA NAP.
Single Channel SyringePipettor (with tip changer) &

Dual Channel ReagentDrop Head
Metal tip barrel for disposable tip system with two
reagent drop pins. Compatible with VERSA Mini NAP
and VERSA Mini LLE.


VERSA Mini Vial Filler Deck


Liquid dispensing system for vials and tubes (48 and 96 tube formats).


VERSA Mini PCR DeckShown with Roche LightCycler &
GeneDisc Adaptor Sets
VERSA automated liquid handling
workstations compatible with Roche’s
light cycler carousel adaptor and
Corbett’s GeneDisc Adaptor.
VERSA Cap Piercing Deck
4- channel cap piercing head
automatically pierces sample
container, aspirates sample, and
dispenses into target plate.
VERSA Sample (Environmental)


Processing Deck


Aspirates environmental samples from
tall tubes and dispenses into specially
designed recipient racks or carousels.
Capable of user-defined dilutions,
repetitive and complex environmental
liquid handling processes. Sonication
washing of the pin after every transfer
minimizes contamination of samples.
VERSA Mini PCR DeckShown with RG 6000 & Roche-Cobas
Adaptor Sets


VERSA automated liquid handling
workstations compatible with
Qiagen’s RG-6000 and Roche-Cobas
Ring Adaptor.


VERSA Mini PCR DeckShown with RG 6000 & GeneDisc
Adaptor Sets


VERSA automated liquid handling
workstations compatible with
Qiagen’s RG-6000 and GeneDisc
adaptor


8 Channel SyringePipettor Head (with Tip Changer)
& Transporter


8 channel Syringe Pipettor and plate transporter
system for VERSA 1000, VERSA 2000 and VERSA 3000.
Dispenses in volumes from 1µL – 1000µL. One channel
can be used independently for mastermix
preparation, cherry picking etc.
4-channel SyringePipettor with Cap-piercing
Head


Used to pierce caps of blood / environmental sample
tubes. Can be integrated with VERSA CAP piercing
system.


8 Channel SyringePipettor Head (with Tip Changer)
8-channel syringe pipettor head. It can be integrated
with VERSA 1000 VERSA 2000 and VERSA 3000.
Dispenses volume from1µL – 1000µL.
Dual Channel ReagentDrop Head
2-channel ReagentDrop for nucleic acid preparation
and liquid-liquid extraction applications. Can be
integrated with VERSA Mini systems.


Liquid Handling Modules: Deck Layouts:


Custom-Vial Filling

  • LH1M-4CSPCP
  • LH1M-8CSTC + VER-PTS
  • LH1M-8CSTC
  • LH2M-1CDSPTC-2CRD + VER-PTS
  • LH2M-1CDSPTC-2CRD
  • LH1M-1CNSFT
  • LH1M-1CSPFT-4”
Versa 1000 2000 3000 Pipettor workstation

Please contact a Gentaur sales representative for a selection audit for the installation of your laboratory. We visit all European Labs with Material safety datasheets and Protocols. Gentaur has a 7/7 24h support line for urgent interventions. If no reparation is possible withing 3 days a replacement unit will be installed.